What is the test method of the switch? We will give you some details here.
金沙国际唯一官网
When we develop a new switching switch and socket, we will do a lot of feasibility experiments to ensure the safety of the switch and socket, which is related to life, not careless.
1. Weldability test.
The top of the terminal is immersed in a tin soldering pool at a depth of 1 inch and the temperature is 230 (+5 C) for 3 (+0.5 seconds).
Note: (1) Welding time should be less than 3 seconds, (2) Welding area should be more than 80%.
2. Welding resistance test.
The temperature of the welding furnace is controlled at 260 (+5 C), the overheating time is 3 (+0.5 seconds), the thickness of the base plate is 1.0, and the temperature of the hand welding should be controlled at 320 (+5 C) for 3 (+0.5 seconds).
Requirements: Must satisfy the body without deformation, the switching switch is satisfied with mechanical and electrical energy.
3. Life test.
No-load: The operator performs 100,000 no-load tests at 60 times per minute.
Requirements: (1) Contact resistance should not exceed 200 m_, (2) other, meet the mechanical and electrical performance.
4. Heat resistance test.
After 96 hours of testing at 85 2 C, the test was conducted at normal room temperature for 1 hour.
Requirements: No abnormal appearance, meet the mechanical and electrical performance.
5. Cold resistance test.
After 96 hours in 90-96% environment, the sample was put in normal environment for 1 hour to test.
Requirements: No abnormal appearance, to meet the mechanical, electrical switching switch performance.
6. Wet test.
After 96 hours in 90-96% environment, the sample was put in normal environment for 1 hour to test.
Requirements: No abnormal appearance, meet the mechanical and electrical performance.
The switching switch is a kind of switch which can turn on or off the circuit through the switch handle to achieve the purpose of switching over the circuit. The commonly used types of switching switches are unipolar bipolar, unipolar three, bipolar two and bipolar three, etc. They are mainly used in various instruments/instruments, electric toys, fax machines, audio equipment, medical treatment, etc. Equipment, beauty equipment and other electronic products.
The switching switch has the characteristics of flexible slider action and stable and reliable performance, so the switching switch is especially widely used in the instrument industry. The reason is that this kind of switch requires the operator to fully understand his own needs. If it is a switch of ordinary quality, it is easy to make mistakes in the process of work, but because of the fact that the switching switch of ordinary quality is easy to make mistakes in the process of work. Once the instrument products work, they must operate normally for a long time. Therefore, special attention should be paid to the switch selection. High-quality switching switch can improve the quality of finished products as a whole, but it is also not easy to cause erroneous operation. Especially, because of the relationship between volume and internal construction, the switching switch is used in Factory Instruments and on-board products. The field has prominent applications, so the switch is the best choice for factory instruments.